Hub
+
  • Hub

Hub

The primary application is second‑type concentrators that comply with the standards of China’s State Grid Corporation. The State Grid’s regulations require metering devices to continue operating for one minute after a power outage. The equipment draws approximately 200 mA at a typical operating voltage of 5 V. Supercapacitors are chosen over batteries for two reasons: outdoors, batteries degrade rapidly, and their service life does not match the overall lifespan of the device. Additionally, supercapacitors reliably deliver the pulsed currents required for communication via 4G networks, GPS, and power lines. Popular models include: 2.7 V – 25 F, 2.7 V – 20 F, 2.7 V – 16 F, and 2.7 V – 10 F. Typically, two individual cells are connected in series. The standard industry solution is two 2.7 V–25 F supercapacitors connected in series.
Consultation

The primary application is for second‑type concentrators that comply with the standards of China’s State Grid Corporation. The State Grid’s regulations require meter‑reading devices to remain operational for one minute after a power outage. The equipment draws approximately 200 mA at a typical operating voltage of 5 V.
Supercapacitors are chosen over batteries for two reasons: in outdoor environments, batteries degrade rapidly, and their service life does not match the overall lifespan of the device. Moreover, supercapacitors reliably deliver the pulsed currents required for communication via 4G networks, GPS, and power lines.
Popular models: 2.7 V – 25 F, 2.7 V – 20 F, 2.7 V – 16 F, 2.7 V – 10 F. By default, two single cells are connected in series. The standard industry solution is two 2.7 V–25 F supercapacitors connected in series.